Skip to content

Homeowner guides

Engineered wood flooring: what to know before you buy

Sage green shaker cabinetry and herringbone flooring in the new Billericay kitchen
Sage green shaker cabinetry and herringbone flooring in the new Billericay kitchen
Contents

The short answer

Engineered wood flooring has a layer of real wood on top of a layered board. Before you buy, check the wear layer thickness, the maker’s rules for underfloor heating and subfloors, how long the boards need to acclimatise and which fitting method suits the room. Those four checks decide how long the floor lasts.

This guide covers what the labels on a box of engineered boards mean, how to choose between thicknesses, what to know if you have underfloor heating and how fitting methods differ. It sits alongside the finishes we plan and supply as part of our interiors work, where flooring is one of the things we source and fit as a single scheme.

Key takeaways

  • Engineered boards are described by total thickness and wear layer, so a 14/3mm board is 14mm thick with a 3mm real wood top layer.
  • The wear layer, not the total thickness, tells you how many times the floor can be sanded.
  • Manufacturers limit floor surface temperature over underfloor heating, and different makers quote different limits, so follow the instructions for the board you buy.
  • Boards usually need to sit in the room before fitting, and new screed must be dry before any wood goes down.
  • Floating, glued and nailed fitting suit different subfloors, so the method should be agreed before you order.

What is engineered wood flooring, and how is it different from solid wood?

Engineered wood flooring is a board made in layers. The top layer is real wood, the part you see and walk on, and it sits on a core beneath. Wood and Beyond’s guide to engineered wood thickness describes the top layer as the wear layer and writes board sizes as total thickness followed by wear layer, for example 10/2mm, which means a 2mm wear layer on an 8mm core. Solid wood flooring is a single piece of timber from top to bottom.

The two behave differently once fitted. Wood and Beyond’s installation guide notes that, because of the movement of a solid wood floor, solid boards are not recommended for floating installation, whereas engineered boards can be floated or glued down. That is one reason engineered boards are so often chosen for extensions and open plan living areas, where a single floor may run through a large space.

Open plan kitchen, dining and living space in the Billericay rear extension
Open plan kitchen, dining and living space in the Billericay rear extension.

How thick should the wear layer be?

Ask for the wear layer figure, because it is the number that matters most. Wood and Beyond says wear layers usually vary between 2mm and 6mm, and that each sand and recoat removes about 1mm of real wood. Ted Todd, another manufacturer, says on its engineered wood thickness page that its 15mm floors have a 3.5mm or 4mm hardwood wear layer, while its 20mm floors have a thicker top layer of up to 6mm.

What the quoted thicknesses mean in practice
What you see on the labelWhat it tells you
Total thickness, for example 14mm or 15mmHow the board sits against door heights, thresholds and any heating requirements
Wear layer, for example 3mm or 4mmHow much real wood there is to sand back over the life of the floor
A pair such as 14/3mmTotal thickness first, then wear layer

A thicker board is not automatically a better board. A thin wear layer on a thick core gives you the depth of a heavy floor with little real wood to refinish, so read both numbers.

What do you need to know about underfloor heating?

Most engineered boards can be used over underfloor heating, but the conditions are strict and they come from the maker, not from us. Ted Todd’s thickness guidance says the surface temperature of a timber floor should not exceed 27°C. Wood and Beyond’s installation guide sets a lower limit of 26°C for the screed surface and asks for flow control valves so the temperature never exceeds it. Two respected suppliers, two different numbers, which is exactly why you follow the instructions for the board you buy.

Wood and Beyond also recommends, in its thickness guide, a total board thickness of no more than 18mm with a wear layer not exceeding 5mm for underfloor heating. Its installation guide adds that new screed with water underfloor heating should be commissioned before the boards are delivered, and that installation over electric underfloor heating would invalidate the warranty, so that point is worth checking before you choose a heating type.

Watch out

Never fit the floor and then switch the heating on at full power. Wood and Beyond warns that laying the floor on a cold surface and then raising the temperature can shock the boards and cause lifting, bowing or delamination of the top layer.

Do engineered boards need to be acclimatised before fitting?

Usually, yes, and the maker’s instructions say how long. In its installation guide, Wood and Beyond asks for boxes to be stored sealed in the middle of the room for at least 48 hours where there is no water underfloor heating, laid flat and opened only on the day of fitting. Where there is water underfloor heating, it asks for longer, with the boards stored in the room for at least 7 to 14 days after the heating has been running.

Site conditions matter as much as the waiting time. The same guide says fitting should start 7 to 10 days after plastering and painting, that windows and doors should be sealed first, that screed should be level, dry and clean, and that a gap of 10 to 15mm should be left at the walls. It gives a permitted moisture content for new screed of under 2% before fitting, and room humidity of 40 to 65% during and after installation.

  1. Finish the wet trades. Plastering, screeding and painting come first, and the screed needs time to dry.
  2. Check the subfloor. It must be solid, flat and dry, with old vinyl and glued down carpet removed.
  3. Store the boards. Keep them in their cartons in the room where they will be laid, for the time the maker specifies.
  4. Fit with the expansion gap. Leave the gap the maker asks for at every wall.

Floating, glued or nailed: which fitting method is right?

The method depends on the boards and the subfloor. Wood and Beyond’s guide lists floating and glue-down as the methods for engineered boards over concrete, plywood and particle board. Floating needs an underlay that acts as a moisture barrier and insulation, and the guide describes it as the least demanding method. Glue-down uses an adhesive applied directly to the subfloor and, over concrete, the guide asks for a two part epoxy damp proof membrane first. It adds that nail-down is advised for floors of 18mm or more, and that thinner boards should be floated or glued.

Dining area in the Billericay rear extension with sliding doors onto the garden
Dining area in the Billericay rear extension with sliding doors onto the garden.

The same guide does not recommend installation in a conservatory or in rooms with large direct windows. If you are planning a glazed extension, our guide to kitchen extension ideas from real Essex projects shows how open plan spaces with big sliding doors are laid out, and it is worth raising your flooring plans with your supplier at the design stage.

Which rooms suit engineered wood?

Living rooms, bedrooms and hallways are the usual choices, and many people also ask about kitchens. There is no single rule, because it comes down to the specific board, its finish and the maker’s instructions. In a kitchen the practical points are a dry, flat subfloor, a moisture barrier, the right expansion gap around fixed units and prompt wiping of spills. If you are choosing a floor for an entrance, our guide to hallway ideas that make a first impression covers the finishes that cope with daily use.

The Billericay kitchen with butler sink, stone worktops and central island
The Billericay kitchen with butler sink, stone worktops and central island.

When flooring is part of a bigger project, decide early. The floor build up affects door heights and thresholds, and underfloor heating has to be designed before the screed goes in. Our whole house renovation and kitchens and bathrooms work is delivered by one team, which makes that sequencing easier. The new kitchen in our Billericay project has herringbone flooring, and you can see it in the Billericay extension case study.

What should you ask a supplier or fitter before you buy?

  • What are the total thickness and the wear layer? Get both numbers in writing.
  • Is the board approved for underfloor heating? Ask for the maximum surface temperature and whether the heating type matters.
  • How long must the boards acclimatise, and where? Ask what room conditions the warranty assumes.
  • Which fitting method is specified for my subfloor? Floating, glued or nailed should be the maker’s recommendation.
  • What does the warranty require? Some makers tie warranty cover to moisture testing and heating commissioning.

Tip

Keep the maker’s installation guide with your paperwork and give a copy to your fitter. If a problem appears later, the warranty will normally be judged against those instructions, so it is worth having proof that they were followed.

Sources and further reading

Frequently asked questions

Can engineered wood go over underfloor heating?

Often yes, but only if the boards, the heating system and the subfloor all suit each other. Manufacturers set a maximum floor surface temperature, 27°C in Ted Todd’s guidance and 26°C in Wood and Beyond’s, and many ask for the heating to be commissioned before the floor goes down. Check the board maker’s underfloor heating instructions before you order.

How many times can engineered wood be sanded?

There is no fixed number, because it depends on the wear layer. Wood and Beyond says each sand and recoat removes about 1mm of real wood, and wear layers usually run from 2mm to 6mm. As a rough guide, a thin 2mm layer leaves little room for sanding, while a 6mm layer leaves more, so ask the supplier for the wear layer figure.

Is engineered wood suitable for a kitchen?

It can be, provided the board maker’s instructions say so and the subfloor is dry and flat. Spills should be wiped up promptly, and the floor should be fitted with the expansion gap and moisture barrier the manufacturer asks for. If the kitchen has underfloor heating, the heating rules apply too, so check both with your supplier before buying.

Can you lay engineered wood over an old floor?

Not over every type of old floor. Wood and Beyond’s installation guide says vinyl and glued down carpet are not suitable subfloors and must be removed, so you reach a solid, flat and dry base. Your fitter should check the existing floor first and tell you whether it needs to be lifted, levelled or covered with a moisture barrier.

Related service

Interiors

Craig Bellamy, founder of Madisons Commercial Solutions, laughing on site in navy work clothing

About the author

Craig Bellamy

Founder and director, Madisons Commercial Solutions

Craig Bellamy founded Madisons Commercial Solutions in 2009 and today leads it as a design and build company based in Latchingdon, Essex. He has 33 years in the industry, much of it delivering show homes for the UK’s leading developers. He is SMSTS qualified and personally oversees the interior finishes on every Madisons project. In May 2025 he spoke at Grand Designs Live.

Enquiries

Tell us what you have in mind

Call 01245 330103 or email [email protected]. We respond to every enquiry within 24 hours.

Get a quote